Search results for "Root canal preparation"

showing 10 items of 26 documents

Thermoplastic Properties of Endodontic Gutta-percha: A Thermographic In Vitro Study

2014

Abstract Introduction Endodontic gutta-percha undergoes deformation at temperatures above 65°C. The temperature influence of heat carriers on gutta-percha cones was investigated in vitro. Methods Six single-rooted extracted teeth were embedded in resin and fixed. The root canals were prepared (ProFile; Dentsply Maillefer, Ballaiques, Switzerland) to different tapers and bisected. Thermographic images when heating the gutta-percha cones (Roeko, Langenau, Germany) with a heat carrier (ML .12; SybronEndo, Orange, CA) at 1 and 5 mm from the working length were made with an infrared thermal imaging camera (ThermaCam P640; Flir Systems, Taby, Sweden). The device temperature was preset at 200°C. T…

Hot TemperatureMaterials scienceThermoplasticSurface PropertiesHeat carrierIn Vitro TechniquesRoot Canal Filling MaterialsThermal conductivityRoot Canal ObturationMaterials TestingHumansIn vitro studyTooth RootComposite materialMean radiant temperaturePenetration depthGeneral Dentistrychemistry.chemical_classificationbiologyThermal ConductivityGutta-perchabiology.organism_classificationIncisorchemistryThermographyInfrared thermal imagingGutta-PerchaRoot Canal PreparationJournal of Endodontics
researchProduct

Simulated root canals preparation time, comparing ProTaper Next and WaveOne Gold systems, performed by an undergraduate student

2020

Background: The aim of this study was to compare the WaveOne Gold and ProTaper Next systems regarding the time spent preparing simulated canals performed by an inexperienced student. Material and Methods: 80 simulated L-shaped canals were randomly divided into two groups (n = 40) and numbered in order of instrumentation. Canals were instrumented with WaveOne Gold (group 1) and ProTaper Next (group 2) systems. The effective instrumentation time and the number of instrumentation cycles were recorded. All procedures were performed by the same operator. Statistical analysis was obtained by the Mann-Whitney, Kruskal-Wallis test with significance of p <0.05. Results: There were no statistically s…

medicine.medical_specialtyRoot canalDental educationEndodonticsOperative Dentistry and Endodontics03 medical and health sciences0302 clinical medicineDental educationmedicineUndergraduate studentStatistical analysisInstrumentation (computer programming)General Dentistry030304 developmental biologyMathematicsUndergraduateOrthodontics0303 health sciencesResearchRoot canal preparation030206 dentistry:CIENCIAS MÉDICAS [UNESCO]EndodonticsPreclinicalmedicine.anatomical_structureUNESCO::CIENCIAS MÉDICASJournal of Clinical and Experimental Dentistry
researchProduct

[The effect of instrumentation on original apical foramen shape using steel vs niti rotatory: computerized analysis]

2002

BACKGROUND. A fundamental requirement to obtain a correct endodontic preparation depends on the respect, during cleaning and shaping, of the original morphology of the apical foramen, (AF), so that the filling material will form a complete seal. METHODS. In our previous studies, in order to verify if this presumption was respected using rotary NiTi instruments with cutting tip, we instrumented extracted teeth characterised by a different degree of root curvatures. Using a standardized system to replace the sample, the original shape of the apical foramen of each tooth was recorded using a computerised technique and then compared to the shape after instrumentation. The data showed difference…

TitaniumTooth ApexSettore MED/28 - Malattie OdontostomatologicheNickelImage Interpretation Computer-AssistedHumansStainless Steelrotary NiTi instruments stainless steel instruments apical foramen shapeRoot Canal PreparationDental Alloys
researchProduct

Evaluation of morphological changes produced by orifice opener systems using computerized tomography (CT)

2009

Objectives: To evaluate modifications in root canal morphology following instrumentation with orifice openers using Computerized Tomography (CT). Study design: Experimental in vitro study. A preoperative CT was performed on 49 molars to measure the root canal cross-sections. After preparing the canals with 6 different nickel-titanium (Ni-Ti) rotary system orifice opener type instruments and Gates Glidden burs, a further CT was made and compared with the preoperative one. Kruskal-Wallis and ANOVA statistical analysis were used. Results: Gates Glidden burs were significantly more aggressive in the coronal portion of the canals, although all the instruments removed more dental tissue in the mo…

MolarOrthodonticsmedicine.medical_specialtybusiness.industryInstrumentationRoot canalRoot canal morphology:CIENCIAS MÉDICAS [UNESCO]Surgerymedicine.anatomical_structureOtorhinolaryngologyCoronal planeUNESCO::CIENCIAS MÉDICASMedicineHumansSurgeryStatistical analysisTomographyDental Pulp CavitybusinessTomography X-Ray ComputedGeneral DentistryBody orificeRoot Canal Preparation
researchProduct

Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.

2009

Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…

Dental Stress AnalysisDental InstrumentsFlexibility (anatomy)Hand techniqueRoot (chord)Normal DistributionDentistryCurvatureNickelmedicineHumansTooth RootPliabilityGeneral DentistryParametric statisticsMathematicsTitaniumAnalysis of Variancebusiness.industryStructural engineeringStainless SteelModels Dentalmedicine.anatomical_structureOtorhinolaryngologyNickel titaniumSurgeryEquipment FailureOral SurgeryDental Pulp CavitybusinessRoot Canal PreparationDental AlloysOral surgery, oral medicine, oral pathology, oral radiology, and endodontics
researchProduct

The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures

2008

The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n…

Root planebusiness.industryOblique caseDentistryEquipment DesignMaterials testingTooth ApexElectronics MedicalTooth FracturesTooth rootTooth ApexMaterials TestingHumansOdontometryTooth RootbusinessGeneral DentistryRoot Canal PreparationAnterior teethMathematicsJournal of Endodontics
researchProduct

Changes in anatomic position of root canal orifices in pluriradicular teeth following re-location during endodontic treatment

2017

Abstract Direct access to the root canals in posterior teeth for endodontic treatment is most frequently facilitated by the straightening of the coronal parts of the root canals, having as a consequence the relocation of the canal orifices on the map of the floor of the pulp chamber ( Christie and Thompson, 1994 ). This procedure intentionally moves the coronal aspect of a canal away from the center of the chamber, while simultaneously removing internal dentin from the pulp chamber walls. The aim of this study was to evaluate the displacement resulting from the relocation of root canal orifices during the initial phase of rotary root canal treatment in molars using the dental operating micr…

AdultMaleMolarAdolescentRoot canalDental CariesEndodonticsPerimeterTooth FracturesYoung Adult03 medical and health sciences0302 clinical medicinestomatognathic systemImage Processing Computer-AssistedmedicineDentinHumansOrthodontics030206 dentistryGeneral MedicineMiddle AgedMolarRoot Canal Therapystomatognathic diseasesmedicine.anatomical_structureInitial phaseCoronal planePosterior teethPulp (tooth)FemaleDental Pulp CavityAnatomyDental Cavity PreparationToothRoot Canal Preparation030217 neurology & neurosurgeryGeologyDevelopmental BiologyAnnals of Anatomy - Anatomischer Anzeiger
researchProduct

Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study

2011

The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…

Dental InstrumentsRadiographyDentistryMandibleStandard deviationDigital imageCadaverEndodontic filesCadaverHumansRadiology Nuclear Medicine and imagingComputer visionGeneral DentistryMathematicsNoise suppressionPixelbusiness.industryResearchGeneral MedicineEquipment DesignRadiography Dental DigitalImage enhancementOtorhinolaryngologySubtraction TechniqueArtificial intelligenceDental Pulp CavitybusinessArtifactsFiltrationRoot Canal Preparation
researchProduct

Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.

2020

Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…

Dental InstrumentsHot Temperatureincidence angle0206 medical engineeringStatistical differencecutting efficiency02 engineering and technology03 medical and health sciencesReciprocating motion0302 clinical medicineNickelStatisticsMaterials TestingGeneral DentistryIncidence (geometry)MathematicsTitaniumheat treatmentIncidenceSignificant difference030206 dentistryEquipment Designreciproc blue020601 biomedical engineeringNickel titaniumHeat treatedreciprocationCalipersRoot Canal PreparationAustralian endodontic journal : the journal of the Australian Society of Endodontology IncReferences
researchProduct

Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment

2009

Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…

AdultMicroscopeComputer scienceRoot canalVideo RecordingComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONDentistryImage processingVideo cameraSensitivity and SpecificityPattern Recognition Automatedlaw.inventionSoftwarelawStereo microscopeImage Processing Computer-AssistedmedicineHumansBicuspidFalse Positive ReactionsComputer visionGeneral DentistryAgedMicroscopybusiness.industryMiddle AgedMolarmedicine.anatomical_structureTherapy Computer-AssistedPattern recognition (psychology)Artificial intelligenceDental Pulp CavitybusinessAlgorithmsRoot Canal PreparationSoftwareTest dataJournal of Endodontics
researchProduct