Search results for "Root canal preparation"
showing 10 items of 26 documents
Three-dimensional analysis of the physiological foramen geometry of maxillary and mandibular molars by means of micro-CT.
2017
The aim of this study was to investigate the physiological foramen diameter, shape and distance between physiological and anatomical apex of maxillary and mandibular first and second molars. Accurate knowledge of the physiological foramina morphology; thus, inherent mechanical shaping technical hindrances, is decisive when taking the corresponding root canal final preparation decision. The morphological dimensions of a total of 1727 physiological foramina were investigated by means of micro-computed tomography. Mean narrow and wide (to a high number, oval) diameters of the physiological foramen were 0.24, 0.22 and 0.33 mm and 0.33, 0.31 and 0.42 mm in mesiobuccal (MB), distobuccal (DB) and …
In vivo evaluation of periodontal microcirculatory changes associated with endodontic treatment.
2014
The purpose of this study was to investigate in vivo the gingival microcirculatory changes associated with endodontic treatment using the continuous wave of condensation technique. MATERIALS AND METHODS: Twenty necrotic one canal roots of 20 cooperative patients of both sexes, aged between 20 and 43 years, were selected. All patients were examined by capillaroscopy before, immediately after endodontic treatment, and after 7 days. The last examination was carried out by the same operator, and repeated twice for each examined area: masticatory, buccal and labial mucosa corresponding to the endodontically treated root. All canals were prepared using a simultaneous technique with Ni-Ti files (M…
Changes in anatomic position of root canal orifices in pluriradicular teeth following re-location during endodontic treatment
2017
Abstract Direct access to the root canals in posterior teeth for endodontic treatment is most frequently facilitated by the straightening of the coronal parts of the root canals, having as a consequence the relocation of the canal orifices on the map of the floor of the pulp chamber ( Christie and Thompson, 1994 ). This procedure intentionally moves the coronal aspect of a canal away from the center of the chamber, while simultaneously removing internal dentin from the pulp chamber walls. The aim of this study was to evaluate the displacement resulting from the relocation of root canal orifices during the initial phase of rotary root canal treatment in molars using the dental operating micr…
Confocal microscopy: a valid approach to evaluate the three-dimensional characteristics of root-end cavities
2013
Objective: To analyze, using confocal microscope, the three-dimensional characteristics of the root-end cavity preparations completed in root apices of extracted teeth determining their area, perimeter, circularity and cavo-surface angle. Study design: Thirty-two single-rooted extracted teeth underwent endodontic treatment and apical resection. Root-end cavities were prepared according to 4 protocols, as follows: Group1, stainless steel ultrasonic tips (SST) at 33 KHz power; Group 2, SST at 30 KHz power; Group 3, diamond-coated ultrasonic tips (DCT) at 30 KHz power; and Group 4, DCT at 33 KHz power. Finally, root-end cavity was evaluated using a confocal microscope, recording its area, peri…
Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment
2009
Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…
Influence of the type of reciprocating motion on the cyclic fatigue resistance of reciprocating files in a dynamic model
2021
Abstract Background The aim of this study was to compare the influence of two novel reciprocating movements on the cyclic fatigue resistance of endodontic reciprocating files. Methods 30 Procodile® (Komet Medical, Lemgo, Germany) files were selected in this study and distributed according to the following study groups depending on the movements to be performed: ReFlex Dynamic (n = 10), ReFlex Smart (n = 10) and Reciproc (n = 10) reciprocating movement. These files were fixed to a specific dynamic cyclic fatigue device designed and manufactured by 3D impression to simulate the pecking motion performed by the operator. The time to failure and the number of cycles of in-and-out of the endodont…
Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.
2020
Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…
Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study
2011
The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…
Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.
2009
Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…
Surface debris of canal walls after post space preparation in endodontically treated teeth: A scanning electron microscopic study
2004
Abstract Purpose To evaluate surface cleanliness of root canal walls along post space after endodontic treatment using 2 different irrigant regimens, obturation techniques, and post space preparation for adhesive bonding. Study design Forty teeth, divided into 4 groups, were instrumented, using Ni-Ti rotary files, irrigated with NaOCl or NaOCl + EDTA and obturated with cold lateral condensation (CLC) or warm vertical condensation (WVC) of gutta-percha. After post space preparation, etching, and washing procedure, canal walls were observed using a scanning electron microscope (SEM). Amount of debris, smear layer, sealer/gutta-percha remnants, and visibility of open tubules were rated. Result…